Overview
The Combined Valve and Ignition system (CVI) has specially been developed for application in gas fired appliances with either intermittent pilot or direct burner ignition.
Features
- The gas controls have been designed to have the S4565/75/85 series ignition control attached directly onto the valve.
- The combined system then provides programmed safe light up, flame supervision and regulation of gas flow to the main burner and/or pilot burner of the appliance.
- The valve (types without pilot outlet) can as well be used as stand alone in direct burner ignition applications.
- A plug with integrated rectifier circuit then has to be used.
- The gas controls are approved in accordance with European standards.
Product Specifications
- Application
- 1:1 Gas:Air
- Item Type
- Product
- Mounting
- 90 degree turned from perpendicular position, side outlet
- Frequency
- 50 Hz
- Customer Special
- General Sale
- Electrical Connections
- Molex 1.1 square pin headers
- Voltage
- 24 Vac
- Operating Temperature Range (F)
- 5 F to 158 F
- Operating Temperature Range (C)
- -15 C to +70 C
- Approvals, CE
- CE Certified. Report 120808
- Approvals, Canadian Gas Association
- CE approved: 120808
- Body Pattern
- Straight-through
- Opening Characteristics
- Integrated Gas/Air 1:1
- Pressure Ratings (kPa)
- 60 mbar
- Inlet/Outlet Size (in.)
- 18.6 mm x 18.6 mm
- Pilot Gas Outlet
- none
- Capacity (m³/hr)
- 3.2 m³/h (air) at pressure drop of 5 mbar
- Pressure Tapping
- Euro-style, inlet and outlet
- Approvals, American Gas Association
- CSA Certificate LR112164
- Type of Fuel
- Natural; LP; Manufactured
- Approvals, Australian Gas Association
- Austrailian Gas Approved: 5354
- Pressure Regulator Setpoint (kPa)
- 0.05 +/- 0.05 mbar
- Ignition Type
- Direct Ignition