AQ25A AQUATROL programmable relay boiler controls for sign-temperature residential hydronic heating systems, provide simplified, energy-efficient control.

Features

  • Displays outdoor temperature on all AQ1000 Series thermostats when used with an AQ12C10 outdoor sensor
  • Intuitive and accessible programming interface and central program of zone set points and setback programming
  • Customizable control settings and schedules provide greater control and comfort and control up to two stages of heat from a single thermostat
  • Zoning Control for up to four zones or expanded to up to 64 zones with additional panels
  • Domestic hot water priority and priority override protection
  • Boiler short cycling protection, boiler post purge and boiler shock prevention from cold water returning to boiler
  • Non-volatile EPROM memory retains program settings during power outage

Product Specifications

Application
Boiler control for zoned hydronic systems
Dimensions (in.)
16 1/2 in wide x 8 in. high x 3 3/8 in deep
Dimensions (mm)
42 cm wide x 20.3 cm high x 8.5 cm deep
Weight (lb)
5.7 lbs
Weight (kg)
2.6 kg
Approvals, Canadian Standards Association
CSA C/US Certified to CSA and UL Standards, File No. LR76030
Tradeline Value
Tradeline
Thermostat Compatibility
AQ1000 Series 2-wire communicating thermostats and most digital thermostats
Setback Program
7 day, up to 2 setback periods/day.
User Interface
LCD Display and a 7 button Key Pad,DIP Switches on zoning modules
Number of Zones
4
Zoning Devices Controlled
Zone pumps or 2-wire valves (line voltage)
Boiler Control Temperature (F)
Differential--2 F to 41 F or Auto (minimum 2 minutes on time)
Boiler Control Temperature (C)
Differential--1 C to 23 C or Auto (minimum 2 minutes on time)
Boiler Heat Post Purge
Off, 10 seconds to 30 minutes (factory default is 30 seconds)
Pump/Valve exercise
30 seconds per 2 weeks of space heating inactivity
R-C Output (on transformer)
38 VA, 24 Vac Class II
R-C Input (on Control and Zoning Modules)
24 Vac Class II (input on Control and Zoning Modules)
Demand Input
Heat Demand (Thermostat R-W), Auxiliary Demand, and DHW Demand--External dry contacts connection only
B-B Communication Bus Terminals
Low voltage, Class II, 2-wire polarity-insensitive, digital communicating link to other Control or Zoning modules.
Zone Module Thermostat Input
Low voltage, Class II, 2-wire polarity-insensitive, digital communicating with power link to AQ1000 series thermostat.
Output Ratings
Boiler (T-T)-- 24 Vac, 0.5A, 12VA; Auxiliary Low Voltage-- 24 Vac, 0.5A, 12VA; Boiler Pump-- 120 Vac/250 Vac 5A, 1/3HP; DHW Pump/Valve-- 120 Vac/250 Vac 5A, 1/3HP; Auxiliary Pump-- Dry contact output, 120 Vac/250 Vac 5A, 1/3 HP
Zone Output Contact Rating
Pumps: 120 Vac/250 Vac, 5A, 1/3 HP,Valves: 24 Vac, 0.5 A, 12 VA
Electrical Connections
Wire-clamp screw terminals, Maximum 2 x 14 AWG each on line voltage terminals
Operating Humidity Range (% RH)
5 to 90% RH, non-condensing
Sensor
Supply/Return Sensor--10 kilohm NTC thermistor at 25 C (77 F) ±0.5F (±0.3C) up to 500 ft (150 M) using 18 AWG or larger wire, Lead Length: 10 ft. (3050 mm); Outdoor Sensor--10 kilohm NTC thermistor at 25 C (77 F) ± 0.5F (±0.3C) up to 500 ft (150 M) using
Replacement Parts
AQ10X38 24 Vac 38 VA transformer,AQ15540B 4-zone pump expansion module,AQ12C11 supply/return/mixed loop sensor,AQ12C10 outdoor sensor,AQ15A00B boiler control module
Temperature Ratings (C)
Panel--0 C to 55 C; Sensor-- -50 C to +110 C
Temperature Ratings (F)
Panel--32 F to 130 F; Sensor-- -58 F to +230 F
Supply Voltage
120V 60 Hz