Skip Ribbon Commands
Skip to main content
SharePoint
Login or Register to view pricing and order.
Item 1 Of 2
Aquatrol Boiler Cntl Pnl - 4 Zone/2 Wire

AQ25042B/U

Aquatrol Boiler Cntl Pnl - 4 Zone/2 Wire

  • Product Info
  • Literature

Overview

AQ250 AQUATROL boiler controls for single temperature, residential hydronic heating systems ensure ample supply of hot water for space heating and domestic uses. Convert single zone heating systems or upgrade relay-logic zoning systems.

Features

  • Use with AQ1000 two-wire communicating thermostats, or most dry contact digital thermostats
  • Offers zoning control for up to four zones and controls up to two stages of heat from a single thermostat
  • Can expand up to 16 zones with AQ255 or AQ257 or up to 64 zones with AQ254 Add-A-Temp panels
  • Line or low-voltage output for zoning equipment, including pumps or valves
  • Features zone synchronization through the zone or Greatest Demand control
  • Includes domestic hot water priority, priority override protection and boiler short cycling protection
  • Automated test feature for quick start-up and simplified troublshooting

Product Specifications

Application
Boiler control for zoned hydronic systems
Dimensions (in.)
13 in wide x 8 in. high x 3 3/8 in deep
Dimensions (mm)
33 cm wide x 20.3 cm high x 8.5 cm deep
Weight (lb)
4.9 lbs
Weight (kg)
2.3 kg
Approvals, Canadian Standards Association
CSA C/US Certified to CSA and UL Standards, File No. LR76030
Tradeline Value
Tradeline
Thermostat Compatibility
AQ1000 Series 2-wire communicating thermostats and most digital thermostats
User Interface
DIP Switches
Number of Zones
4
Zoning Devices Controlled
Zone pumps or 2-wire valves (line voltage)
Boiler Heat Post Purge
30 seconds (sent to DHW tank or Zone of Greatest Demand - selectable)
Pump/Valve exercise
30 seconds per 2 weeks of space heating inactivity
R-C Output (on transformer)
38 VA, 24 Vac Class II
R-C Input (on Control and Zoning Modules)
24 Vac Class II
Demand Input
Heat Demand (Thermostat R-W) and DHW Demand--External dry contacts connection only
B-B Communication Bus Terminals
Low voltage, Class II, 2-wire polarity-insensitive, digital communicating link to other Control or Zoning modules.
Zone Module Thermostat Input
Low voltage, Class II, 2-wire polarity-insensitive, digital communicating with power link to AQ1000 series thermostat.
ZR-ZC Contact Rating
120 to 240 Vac, 1/3 HP
Output Ratings
Boiler (T-T)-- 24 Vac, 0.5A, 12VA; Boiler Pump-- 120 Vac/250 Vac 5A, 1/3HP; DHW Pump/Valve-- 120 Vac/250 Vac 5A, 1/3HP; Auxiliary Pump-- Dry contact output, 120 Vac/250 Vac 5A, 1/3 HP
Zone Output Contact Rating
Pumps: 120 Vac/250 Vac, 5A, 1/3 HP,Valves: 24 Vac, 0.5 A, 12 VA
Electrical Connections
Wire-clamp screw terminals, Maximum 2 x 14 AWG each on line voltage terminals
Operating Humidity Range (% RH)
5 to 90% RH, non-condensing
Sensor
Supply/Return Sensor--10 kilohm NTC thermistor at 25 C (77 F) ±0.5F (±0.3C) up to 500 ft (150 M) using 18 AWG or larger wire, Lead Length: 10 ft. (3050 mm); Outdoor Sensor--10 kilohm NTC thermistor at 25 C (77 F) ± 0.5F (±0.3C) up to 500 ft (150 M) using
Replacement Parts
AQ10X38 24 Vac 38 VA transformer,AQ15540B 4-zone pump expansion module,AQ12C11 supply/return/mixed loop sensor,AQ15000B boiler control module
Temperature Ratings (C)
Panel--0 C to 55 C; Sensor-- -50 C to +110 C
Temperature Ratings (F)
Panel--32 F to 130 F; Sensor-- -58 F to +230 F
Supply Voltage
120V 60 Hz

Marketing Collateral

Sales/Promotional Materials-Hydronics Technical Reference Book - Aquatrol Hydronic Boiler Controls

Sales/Promotional Materials-Resideo Hydronic Heating Solutions Brochure (English)

Sales/Promotional Materials-Brochure for Aquatrol Hydronic Controls 2009-2010 Enhancements (French)

Sales/Promotional Materials-Counter mat insert for Aquatrol Hydronic Controls Selection Chart (English)

Sales/Promotional Materials-Brochure for Aquatrol Hydronic Controls 2009-2010 Enhancements (English)

Sales/Promotional Materials-Aquatrol Hydronic Controls easel card

Sales/Promotional Materials-Aquatrol Hydronic Controls (French)

POP Products-Aquatrol AQ2000 Series (French)

Sales/Promotional Materials-Aquatrol Hydronic Controls

Sales/Promotional Materials-Aquatrol Hydronic Controls homeowner brochure

Sales/Promotional Materials-Aquatrol Hydronic Controls

Product Selections/Comparisons-Aquatrol Product Selection Tool

Technical Documents

Installation Materials-Quick Installation Guide for AQ250 Series Hydronic Control Panels

Product Data and Specifications-Product Data for AQ250 Series Hydronic Control Panels (English)

Installation Materials-Aquatrol Thermostat Wiring

Installation Materials-Installation Job Record for AQ25042B RelayPLUS Zone Synchronizing Boiler Control (English)

Installation Materials-Mounting Template for AQ25042B, AQ25044B or AQ25110B Control Panel Mounting (English)

Installation Materials-Installation Job Record for AQ25044B RelayPLUS Zone Synchronizing Boiler Control (English)

May we also suggest

3-Speed Circulation Pump

PC3F1558IUF00/U

3-Speed Circulation Pump

3-Speed Circulation Pump

PC3F2699IUF00/U

3-Speed Circulation Pump

3-Speed Circulation Pump

PC3F4344IUF00/U

3-Speed Circulation Pump