Skip Ribbon Commands
Skip to main content
SharePoint
Login or Register to view pricing and order.
Item 1 Of 4
Cadmium-Sulfide Flame Detector with 30 in. leads, Type "J" mounting bracket and 120320 Cad Cell
Cadmium-Sulfide Flame Detector with 30 in. leads, Type "J" mounting bracket and 120320 Cad Cell

C554A1216/B

Cadmium-sulfide flame detector with 30 in. leads, type "J" mounting bracket

Find Equivalent or Replacement Products.

  • Product Info
  • Literature
  • Accessories & Replacement Parts

Overview

Photoconductive flame sensing device for sequencing oil burner systems.

Features

  • On flame failure, the light sensitive cadmium sulfide cell, in conjunction with flame sensing circuitry, causes the Protectorelay® control to shutdown the main oil burner.
  • Glass-to-metal hermetic seal in plug-in cell prevents deterioration by humidity, soot or oil fumes.
  • Replaceable CAD Cell

Product Specifications

Application
Oil fired burners
Dimensions (in.)
5/8 in. high x 1 in. long x 1/2 in. wide
Dimensions (mm)
16 mm high x 25 mm long x 13 mm w
Used With
R4166, R4184, R8182, R8184, R8185, R8404, R8991, R7997, R7184, R7284
Item Type
Product
Mounting
Type J bracket
Approvals, Underwriters Laboratories Inc.
UL Listed: File no. MP268, Vol. 39, Sec. 1, Guide MCCZ
Approvals, Canadian Standards Association
CSA Component Listed: File no. LR95329-1
Electrical Connections
lead wires: NEC Class 1
Replacement Parts
120320 Replacement Cad Cell. 7.5 mA minimum sensitivity at 2 ft. candles; 130367 Replacement Cad Cell. 12.0 mA minimum sensitivity at 2 ft. candles.
Power Consumption
7.5 mA
Ambient Temperature Range (C)
60 C maximum
Ambient Temperature Range (F)
140 F maximum
Lead Length (in.)
30 in.
Lead Length (mm)
762 mm
Sensitivity
Minimum sensitivity at 2 ft candles

Accessories

4074BJS/U

Cad cell mounting bracket assembly, including nut and screw

Replacement Parts

120320/U

Replacement Cell Assembly, 400-1600 Ohm Sensitivity

130367/U

Replacement Cell Assembly, 400-1000 Ohm Sensitivity