Pilot Burner - nat gas w. BCR-18 orifice

Q3452C2082/U

Pilot Burner - nat gas w. BCR-18 orifice

  • Product Info
  • Literature

Overview

The Q3452 Intermittent Pilot Burners provide pilot flame ignition and sensing for intermittent ignition systems. They consist of a pilot burner with a two-rod spark igniter and flame sensor, orifice assembly, and compression fitting.

Features

  • Two-rod Pilot Burner/Igniter Sensor is used with Intermittent Ignition Two-rod systems.
  • 15,000V open circuit spark ignition.
  • Natural and LP gas orifices available.
  • Variety of target styles available.
  • Variety of mounting brackets available.

Product Specifications

Application
Pilot Burner
Includes
Spark/Flame rod ass'y
Used With
S8600A,B,C,J,K; S8610A,B,C,U; S8620C; S8670J,K
Item Type
Product
Mounting
Bracket Style C
Approvals, Underwriters Laboratories Inc.
UL Listed: MCUR2.MH63583
Customer Special
Armstrong
Type of Gas
Natural
Approvals, Canadian Gas Association
CGA Certified: 1029-ABI-8365A
Aeration
Non-primary
Compression Fitting Size
1/4 in.
Compression Fitting Length
3/4 inch
Orifice
BCR-18 (0.018 in.)
Tip Style
Single
Direction of Front Tip
(F) Front
Dual Rod or Single Rod
Dual Rod
Pilot Btuh
1000
Length (in.)
Ignition Wire--47 in.
Length (mm)
1194 mm