1/2 in. NPT x 1/2 in. NPT Intermittent Hot Surface Pilot Ignition SmartValve® Control with standard opening and 3.2 in. wc pressure regulator setting

SV9540Q2464/U

1/2x1/2 NPT Intermtt Hot Surf.Pilot Ign.

Find Equivalent or Replacement Products.

  • Product Info
  • Literature

Overview

The SmartValve® System Controls combine gas flow control and electronic intermittent pilot sequencing functions into a single unit. The Q3450 or Q3480 Pilot hardware supplies the low voltage igniter, flame sensor and pilot burner. These ignition system controls provide all gas ignition safety functions by controlling gas flow, ignition source, and a 120 Vac or 240 Vac combustion air blower. The controls also monitor the appliance airflow proving switch and limit string to assure proper appliance operation, and provide prepurge, postpurge, and timed trial for pilot ignition with 100 percent shutoff and continuous retry. Includes a diagnostic LED indicates system status.

Features

  • These controls communicate directly with an electronic fan timer (ST9160 Electronic Fan Timer for single stage applications; ST9162 Electronic Fan Timer for two-stage applications) in typical forced warm air furnace applications.
  • It can directly interface with the appropriate power supplies and a system thermostat for additional appliance applications.
  • When controlled directly by a thermostat, these controls do not provide a postpurge function, because power to the control is removed when the thermostat call for heat ends.
  • The Systems are suitable for a wide range of fan-assisted combustion gas-fired appliances including furnaces, rooftop furnaces, boilers, unit heaters, infrared heaters, water heaters and commercial cooking appliances.

Product Specifications

Dimensions (in.)
3.2 in. wide x 4.9 in. high x 4.1 in.long
Dimensions (mm)
81 mm wide x124 mm high x 104 mm long.
Item Type
Product
Mounting
0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Electrical Ratings
24 Vac
Frequency
50 Hz; 60 Hz
Customer Special
ICP
Voltage
Call for heat--24 Vac, 60 Hz
Flame Failure Response Time (sec)
1.6 sec @ 3 µA
Ambient Temperature Range (C)
-40 C to +79 C
Ambient Temperature Range (F)
-40 F to +175 F
Ignition System Type
Intermittent Hot Surface Pilot Ignition
Ignition Sequence
Intermittent Pilot
Type of Gas
Natural
Flame Sense
Two Rod
Ignition Source
Pilot
Ignition Trials To Lockout
continuous retry
Ignition Trial Time (sec)
90 sec
Body Pattern
Straight-through
Opening Characteristics
Standard
Pressure Regulator Setting (psi)
3.2 in. wc
Pressure Regulator Setting (kPa)
0.80 kPa
Inlet/Outlet Size (in.)
1/2 in. NPT x 1/2 in. NPT
Capacity (ft³/hr)
Maximum at 1 in. P.D.--150 ft³/hr; Maximum--200 ft³/hr; Minimum--20 ft³/hr
Capacity (m³/hr)
Maximum at 1 in. P.D.--4.2 m³/hr; Maximum--5.7 m³/hr; Minimum--0.6 m³/hr
Pressure Tapping
1/8 in. - NPT