Skip Ribbon Commands
Skip to main content
SharePoint
Login or Register to view pricing and order.
Item 1 Of 3
Low Volt Elec. Thermostat, Elec/Flr Heat

TH114-AF-024T/U

Low volt electric heating (ambient and floor) manual thermostat

  • Product Info
  • Literature

Overview

The TH114 Series delivers the features that matter most in a non-programmable thermostat: an easy-to-read backlit display, slim contemporary design and precise temperature control.

Features

  • Three choices of temperature control in a single thermostat (Ambient, Floor, or Ambient with Floor temperature limits)
  • 5 mA ground fault circuit interrupter (GFCI) on GA models
  • 15 mA equipment ground fault protection devices (EGFPD) on GB models
  • GFCI and EGFPD test light verifies safety control is functioning properly and alerts if a leak is detected
  • Advanced temperature control ensures total comfort by minimizing temperature swings
  • ON/STANDBY switch enables thermostat shutdown at the end of heating season for added security
  • On-screen heating power indicator gives at-a-glance verification of power being used
  • Backlit display
  • Battery-free

Product Specifications

Application
Radiant floor
Dimensions (in.)
4.9 in. X 2.8 in. X 0.9 in.
Dimensions (mm)
124 mm X 70 mm X 23 mm
Includes
Aube AC112-01 North American Sensor, 15 feet (4.6 m)
Used With
Aube RC840/RC840T Series Electromechanical Relays; Aube AC112-01 North American Sensor, 15 feet (4.6 m)
Comments
With Backlight & On/Standby Switch
Item Type
Product
Mounting
Vertical
Electrical Ratings
Max. 0.5 A @ 24 VAC
Approvals, Canadian Standards Association
Approved; Compliant to CAN/CSA-C828-06
Supply Voltage
24 Vac
Switch Positions (System)
AF (ambient + floor)/ F (floor only)
Operating Temperature Range (F)
32 F to 122 F
Operating Temperature Range (C)
0 C to 50 C
Power Method
Hardwired
Ambient Temperature Range (C)
AF mode: 0 C to 50 C; F mode: 0 C to 60 C
Ambient Temperature Range (F)
AF mode: 32 F to 122 F; F mode: 32 F to 140 F
Color
White
Sensor Element
Thermistor
Accuracy (F)
0.9 F
Accuracy (C)
0.5 C
Differential Temperature (F)
1 F
Differential Temperature (C)
0.5 C
Switch Type
External electromechanical relay
Terminal Designations
R, C, W
Setting Temperature Range (F)
40 F to 86 F room temperature; 40 F to 104 F floor temperature
Setting Temperature Range (C)
5 C to 30 C room temperature; 5 C to 40 C floor temperature
Parts Needed for Operation (not included)
External electromechanical relay