Skip Ribbon Commands
Skip to main content
SharePoint
Login or Register to view pricing and order.
Item 1 Of 1
European Manual Electronic Thermostat

TH131-AF-230-OEM/U

Line volt European manual electronic thermostat for electric floor heating applications

  • Product Info
  • Literature

Product Specifications

Application
Electric Radiant Floor
Dimensions (in.)
3.1 in. X 3.1 in. X 0.6 in.
Dimensions (mm)
78.9 mm X 78.9 mm X 16.3 mm
Includes
Thermostat wall plate; Snubber assembly; AC130-01 North American 10-ft sensor
Used With
Aube AC130-01 European floor sensor
Comments
On/Off Switch; Min. and max. temperature limits; Terminal for pilot wire programmer
Mounting
Vertical
Electrical Ratings
3450 W (NI) @ 15 A max. (resistive only), 230 VAC
Frequency
50 Hz
Electrical Connections
Terminal block
Supply Voltage
230 Vac
Switch Positions (System)
AF (ambient + floor)/F (floor only); On/Standby
LEDs
Pilot wire indicator; Heating indicator
Power Method
Hardwired
Color
White
Sensor Element
Thermistor
Accuracy (F)
± 0.36 F
Accuracy (C)
± 0.5 C
Switch Type
Relay
Terminal Designations
Power: 1 and 5; Load: 2 and 4; Pilot Wire: 3; Floor sensor:6 and 7
Operation
AF/F configuration switch must be set to AF for this thermostat to be operational.
Changeover
Automatic - receives orders from the Energy Management Program (pilot wire)
Setting Temperature Range (C)
7 C (frost protection), 15 C to 35 C
Cycles per Hour
4 CPH
Heat Current
15 A (resistive only)