Skip Ribbon Commands
Skip to main content
SharePoint
Login or Register to view pricing and order.
Item 1 Of 1
Non-Programmable Controller, Low Volt

TH146-N-U/U

Low volt non-programmable 3 heat/cool conventional and 4H/2C heat pump thermostat

This product is obsolete, but it can be purchased while supplies last.

  • Product Info
  • Literature
  • Accessories & Replacement Parts

Overview

This thermostat features a 2-wire user console connection, idea for retrofits. This TH164-N-U includes a non-programmable console, a control module, and an outdoor temperature sensor

Features

  • Installer mode bypasses compressor lockout delay for quicker installations
  • Removable connector strip simplifies wiring
  • Selectable cycles (2 to 6 per hour) optimize system to heating/cooling application
  • Control module for equipment connections can be installed near furnace/air handler, only 2 wires required for console connection
  • Automatic changeover between heating and cooling
  • Backlit console display shows indoor and outdoor temperature, or indoor temperature and humidity level
  • Complete defrost sequence protection (requires AC146-410 air duct temperature sensor)
  • Keypad lock for console prevents tampering

Product Specifications

Application
Heat/Cool or Heat Pump with Auxiliary Heat
Dimensions (in.)
User console: 3.1 in. X 3.1 in. X 1 in.; Control module: 3 in. X 4.3 in. X 1 in.
Dimensions (mm)
Control module: 76 mm X 109 mm X 25 mm; User Console: 79 mm X 79 mm X 24 mm
Includes
CT280-3H3C control module, TH146 user console, AC144-03 Outdoor Temperature Sensor (3-m/10-ft) with Mounting Clip
Used With
Aube CT240/CT241 Telephone Controllers; Aube AC146-410 Air Duct; Temperature Probe; Aube RC845 add-on fossil fuel relay; Aube AC130-12 wallplate
Comments
Two-piece Design: Two-wire User Console Connection, Dual-energy Input, Backlight
Item Type
Product
Mounting
Control Module: Horizontal; User console: Vertical
Stages
Up to 3 Heat/3 Cool Conventional; Up to 4 Heat/2 Cool Heat Pump
Operating Humidity Range (% RH)
0% to 95%, non-condensing
Supply Voltage
24 Vac
Switch Positions (System)
HEAT-OFF-COOL-AUTO-EM.HEAT
Switch Positions (Fan)
AUTO/ON
Operating Temperature Range (F)
32 F to 122 F
Operating Temperature Range (C)
0 C to 50 C
LEDs
Console: System Fault, Em. Heat, Dual-energy; Module: 1 per output
Power Method
Hardwired
Ambient Temperature Range (C)
0 C to 70 C
Ambient Temperature Range (F)
32 F to 158 F
Color
White
Sensor Element
Thermistor
Accuracy (F)
±1 F
Accuracy (C)
± 0.5 C
Switch Type
Relay
Terminal Designations
R, C, Y1, Y2, Y3, W1, W2, W3, G, (O/B), L
Changeover
Auto or Manual Selectable
Setting Temperature Range (F)
40 F to 86 F
Setting Temperature Range (C)
5 C to 30 C
Cycles per Hour
2-6 CPH (Heating and Cooling)
Cool Current
1.0 A
Heat Current
1.0 A
Fan Current
1.0 A
Fan Operation
On/Auto

Accessories

CT240-01/U

Telephone controller with 2 simultaneous outputs for thermostats or appliances

CT241-01/U

Telephone controller with 4 independent outputs for thermostats or appliances

AC146-410/U

Temperature sensor for air duct and air handlers

AC130-12-P10/U

Pack of 10 Wall plates for thermostat

RC845/U

Add-on fossil fuel relay. Control gas, oil furnace burner or electric furnace.