Product Specifications

Hazmat Information
Button cell contained in equipment, Lithium metal button cells only contained in equipment, excepted per PI970
Application
Heat/Cool or Heat Pump with Auxiliary Heat
Dimensions (in.)
3-3/4 in. high x 6 in. wide x 1-3/8 in. deep
Dimensions (mm)
99 mm high x 152 mm wide x 35 mm deep
Comments
Selectable: Programmable or Non-Programmable; The L terminal is an input or output.
Item Type
Product
Mounting
Horizontal
Electrical Ratings
20 to 30 Vac or 750 mV
Frequency
50 Hz; 60 Hz
Stages
Up to 2 Heat/2 Cool Conventional; Up to 2 Heat/1 Cool Heat Pump
Operating Humidity Range (% RH)
5 to 90% RH, non-condensing
Switch Positions (System)
HEAT-OFF-COOL-AUTO-EM.HEAT
Switch Positions (Fan)
AUTO-ON-CIRC
Power Method
Battery or Hardwired
Color
Premier White®
Sensor Element
Thermistor
Differential Temperature (F)
± 1 F
Differential Temperature (C)
±0.5 C
Programmability
7 Day Program or Non-Programmable
Terminal Designations
R, RC, W-O/B, Y, G, C, W2-Aux, Y2/E, L, S1, S2
Display Size
10 sq in.
Changeover
Auto or Manual Selectable
Setting Temperature Range (F)
Heat: 40 F to 90 F; Cool: 50 F to 99 F
Setting Temperature Range (C)
Heat: 4.5 C to 32 C; Cool: 10 C to 37 C
Cool Current
1.0 A running
Heat Current
1.0 A running
Fan Current
0.6A running