Overview
Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit.
Features
- Intermittent ignition is on while the burner is on.
- Solid state flame sensing circuit.
- External button to manually reset safety switch after lockout.
- Enclosed safety switch must be manually reset after safety shutdown.
- R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment.
- Mounts on standard 4 x 4 in. junction box.
- C554A Cadmium Sulfide Flame Detector and a 24 Vac thermostat required.
Product Specifications
- Dimensions (in.)
- 4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep
- Dimensions (mm)
- 111 mm high x 104 mm wide x 64 mm deep
- Temperature Range (F)
- -40 F to +130 F
- Temperature Range (C)
- -40 C to +54 C
- Item Type
- Product
- Mounting
- Mounts on standard 4 x 4 in. junction box
- Approvals, Underwriters Laboratories Inc.
- UL Component Recognized; File no. MP268, guide no. MCCZ2
- Tradeline Value
- Tradeline
- Ignition Type
- Intermittent
- Timing, Safety Switch
- 45 sec.
- Electrical Ratings, Contacts (full load)
- 7.4 A @ 120 Vac; 3.7 a @ 240 Vac
- Electrical Ratings, Contacts (locked rotor)
- 44.4 A @ 120 Vac; 22.2 A @ 240 Vac
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.