Overview
These ignition modules provide ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances.
Features
- Provide up to 1.0 A pilot and 1.0 main valve current rating.
- Use a separate igniter and sensor (Q179C with igniter and sensor mounted on one bracket, or Q354 sensor with Q345, Q346, Q348, Q362 or Q381 igniter-sensor recommended.)
- Can be used on natural on LP gas; they provide 100 percent shutoff on ignition failure.
- Lock out on shutoff.
- Manual reset is required.
Product Specifications
- Dimensions (in.)
- 3 15/16 in. high x 5 7/16 in. wide x 2 5/8 in. deep
- Dimensions (mm)
- 100 mm high x 138 mm wide x 67 mm deep
- Item Type
- Product
- Electrical Ratings
- 24 Vac
- Frequency
- 60 Hz
- Approvals, Canadian Standards Association
- Design Certified
- Flame Failure Response Time (sec)
- 2 seconds maximum
- PrePurge
- None
- Ambient Temperature Range (C)
- -40 C to +79 C
- Ambient Temperature Range (F)
- -40 F to +175 F
- Ignition System Type
- Intermittent Pilot
- Ignition Sequence
- Lockout
- Typical Gas Control
- VR8204, VR8304
- Type of Gas
- Natural or LP
- Flame Sense
- Single Rod
- Ignition Source
- Internal high voltage spark generator
- Ignition Trials To Lockout
- 1
- Lockout Timing
- 90 seconds
- Ignition Trial Time (sec)
- 90 sec
- Maximum Valve Load @ 24 Vac (Amps)
- 1A Pilot, 1A Main @ 24Vac
- Typical Ignition Hardware
- Q345, Q3451