Overview
Universal hot surface ignition module replaces multiple field installed hot surface ignition modules supplied by Resideo, White-Rodgers, Robertshaw and Johnson. Uses a 120 VAC igniter. Includes cross reference, instructions, and accessories for easy replacement.
Features
- Replaces over 800 White-Rodgers, Robertshaw and Resideo hot surface ignition models.
- For 120 Vac (up to 5.0A) surface igniter (Norton 201/271 or equivalent).
- S8910U 3000 Series has LED status indicator and microammeter ports for easy trouble shooting
- For local (single rod) or remote (dual rod) rectification type flame sensing.
- Contains easy-to-use cross reference and instructions plus the accessories required to replace the existing hot surface ignition module.
- Provides one or three ignition trials (four-second or seven-second trials) per call for heat.
- Field selectable number of ignition trials and trial time based on unit being replaced.
- Igniter warm up time: 7 (12 seconds second and third trial), 17 (27 seconds second and third trial), 34, or 45 seconds
Product Specifications
- Dimensions (in.)
- 5 1/4 in. high x 4 1/16 in. wide x 1 15/16 in. deep
- Dimensions (mm)
- 133 mm high x 103 mm wide x 49 mm deep
- Item Type
- Product
- Electrical Ratings
- 24 Vac
- Frequency
- 50 Hz; 60 Hz
- Approvals, Canadian Standards Association
- Design Certified
- Tradeline Value
- Tradeline
- Flame Failure Response Time (sec)
- 1.5 sec.
- PrePurge
- 32 seconds
- Ambient Temperature Range (C)
- -40 C to +79 C
- Ambient Temperature Range (F)
- -40 F to +175 F
- Ignition System Type
- Direct Hot Surface Ignition
- Ignition Sequence
- The number of trials for ignition and trial time is determined by the dip switch selection.
- Typical Gas Control
- VR8205, VR8305
- Type of Gas
- Natural or LP
- Flame Sense
- Single Rod or Two Rods
- Ignition Source
- Line Voltage (120 VAC) Hot Surface Element (Norton Model 201 or 270)
- Ignition Trials To Lockout
- 1 or 3
- Lockout Timing
- 4 sec. or 7 sec.
- Ignition Trial Time (sec)
- 4 sec. or 7 sec.
- Maximum Valve Load @ 24 Vac (Amps)
- 2A
- Typical Ignition Hardware
- Norton 201, Norton 271, Q354
- Between Trial Time (sec)
- (2) 96 sec (32 Seconds Prepurge and 64 seconds interpurge)
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.