Overview
Universal Integrated Furnace Control offers universal compatibility and diagnostics. It replaces a large number of furnace control models in single-stage warm air furnaces. Uses 120Vac hot surface igniter. Includes instructions and special wire harnesses for easy replacement.
Features
- • Cross reference and wire harnesses provided for simple replacement over 195 existing furnace controls.
- Main burner ignition using a 120V hot surface igniter.
- Flame rectification circuit to monitor flame presence.
- Monitoring of system pressure switch, high temperature limit, and rollout functions.
- Appliance operation/safety requirements controlled via microprocessor.
- Controls circulating fan motor based on appliance requirements, in response to a conventional low voltage thermostat.
- LED system status, performance and diagnostic indication.
- Twinning capability
Product Specifications
- Application
- Single stage warm air furnaces
- Item Type
- Product
- Frequency
- 60 Hz
- Operating Humidity Range (% RH)
- 0% to 95% non-condensing
- Operating Temperature Range (F)
- -40 F to +175 F
- Operating Temperature Range (C)
- -40 C to +79 C
- Flame Failure Response Time (sec)
- 2 Seconds max @ 1µA
- PrePurge
- 30 seconds
- PostPurge
- 15 seconds
- Cool Fan On Delay
- 5 seconds
- Cool Fan Off Delay
- 0 or 60 seconds
- Line Voltage
- 120 Vac (97-132 Vac)
- Low Voltage
- 24V (18-30 Vac)
- Igniter Current
- 5 A resistive @ 120VAC
- Thermostat Anticipator Setting
- (Stage 1 only) 100mA
- HSI Warmup Time
- 17/27 or 30/30 seconds
- Trial For Ignition
- 4, 6, or 8 seconds
- Interpurge
- 60 seconds
- Ignition Trials
- Three, two retries if flame is not sensed
- Number of LEDs
- 3
- Heat On Fan Delay
- 30 or 60 seconds
- Heat Off Fan Delay
- 60, 90, 120, or 180 Seconds
- Gas Control Used With
- Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended.
- Cooling Contactor Used With
- Any 24Vac contactor rated at 1.0A or less
- Induced Draft Blower Load
- 2.2FLA / 25LRA max @120Vac
- Ciculator Load
- 14.5FLA / 25LRA max @120Vac
- Type of Fan Used With
- Standard Induction-Type Circulating Fan
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.