Overview
ST9103A integrates control of burner and circulating fan operations in an oil furnace.
Features
- Central appliance wiring point simplifies service
- Oil burner primary control
- Fixed or field-adjustable heat fan on delay
- Field adjustable heat fan off delay
- Controls two speed circulating fan
Product Specifications
- Application
- A single circuit board providing combustion air blower control, two speed circulating air blower control, oil primary control, limit circuit inputs, thermostat wiring terminations, & a central appliance wiring point for an oil fixed furnace.
- Frequency
- 50 Hz; 60 Hz
- Approvals, Underwriters Laboratories Inc.
- Listed: Report MP466
- Approvals, Canadian Standards Association
- Certified: File No. LR95329-17
- Ambient Temperature Range (C)
- -40 C to +66 C
- Ambient Temperature Range (F)
- -40 F to +150 F
- Replaces
- ST9103A1002
- Heat Fan On Delay
- fixed, 45 sec
- Heat Fan Off Delay
- adj. 60, 90, 120, 150 sec (set at 150 sec)
- Cool Fan On Delay
- fixed 0 sec
- Cool Fan Off Delay
- fixed 0 sec
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.