Product Specifications
- Application
- Electric Radiant Floor
- Dimensions (in.)
- 3.1 in. X 3.1 in. X 0.6 in.
- Dimensions (mm)
- 78.9 mm X 78.9 mm X 16.3 mm
- Includes
- Thermostat wall plate; Snubber assembly; AC130-01 North American 10-ft sensor
- Used With
- Aube AC130-01 European floor sensor
- Comments
- On/Off Switch; Min. and max. temperature limits; Terminal for pilot wire programmer
- Mounting
- Vertical
- Electrical Ratings
- 3450 W (NI) @ 15 A max. (resistive only), 230 VAC
- Frequency
- 50 Hz
- Electrical Connections
- Terminal block
- Supply Voltage
- 230 Vac
- Switch Positions (System)
- AF (ambient + floor)/F (floor only); On/Standby
- LEDs
- Pilot wire indicator; Heating indicator
- Power Method
- Hardwired
- Color
- White
- Sensor Element
- Thermistor
- Accuracy (F)
- ± 0.36 F
- Accuracy (C)
- ± 0.5 C
- Switch Type
- Relay
- Terminal Designations
- Power: 1 and 5; Load: 2 and 4; Pilot Wire: 3; Floor sensor:6 and 7
- Operation
- AF/F configuration switch must be set to AF for this thermostat to be operational.
- Changeover
- Automatic - receives orders from the Energy Management Program (pilot wire)
- Setting Temperature Range (C)
- 7 C (frost protection), 15 C to 35 C
- Cycles per Hour
- 4 CPH
- Heat Current
- 15 A (resistive only)
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.