Skip Ribbon Commands
Skip to main content
SharePoint
Login or Register to view pricing and order.
  • Product Info
  • Literature

Overview

This thermostat features a 2-wire user console connection—ideal for retrofits. The TH146-P-U includes a programmable console, a control module, and an outdoor temperature sensor.

Features

  • Installer mode bypasses compressor lockout delay for quicker installations
  • Removable connector strip simplifies wiring
  • Control module for equipment connections can be installed near furnace/air handler. Only 2 wires required for console connection
  • Automatic Changeover between heating and cooling
  • Backlit console display shows indoor and outdoor temperatures, plus indoor humidity level
  • Complete defrost sequence protection (requires AC146-410 air duct temperature sensor)
  • Keypad lock for console prevents tampering
  • Dehumidifier/air exchanger output with automatic minimum air exchange time.

Product Specifications

Application
Heat/Cool or Heat Pump with Auxiliary Heat
Dimensions (in.)
Control Module: 3.8 in. X 5.4 in. X 1.2 in.; User console : 3.1 in. X 3.1 in. X 1 in.
Dimensions (mm)
User Console : 79 mm X 79 mm X 24 mm; Control Module: 95 mm X 137 mm X 30 mm
Includes
CT280-2H1C control module; TH146-P console; AC144-03 Outdoor Temperature; Sensor (10 ft/3 m) w/Mounting clip
Comments
Air exchange function; Removable control strips to simplify wiring; Dual-Energy Input; Backlit display; Remote input for telephone controller
Item Type
Product
Mounting
Vertical
Stages
Up to 4 Heat/2 Cool Heat Pump; Up to 3 Heat/3 Cool Conventional
Operating Humidity Range (% RH)
0% to 95%, non-condensing
Supply Voltage
24 Vac
Switch Positions (System)
HEAT-OFF-COOL-AUTO-EM.HEAT
Switch Positions (Fan)
AUTO-ON
Operating Temperature Range (F)
32 F to 122 F
Operating Temperature Range (C)
0 C to 50 C
Power Method
Hardwired
Color
White
Sensor Element
Thermistor
Differential Temperature (F)
± 1 F
Differential Temperature (C)
±0.5 C
Switch Type
Relay
Programmability
7 Day program
Terminal Designations
R, C, Y1, Y2, Y3, W1, W2, W3, G, (O/B), L
Changeover
Auto or Manual Selectable
Setting Temperature Range (F)
40 F to 86 F heating; 59 F to 104 F cooling
Setting Temperature Range (C)
15 C to 40 C cooling; 5 C to 30 C heating
Humidification Setting Range
5% to 60%
Dehumidification Setting Range
5% to 60%
Cool Current
1.0 A
Heat Current
1.0 A
Fan Current
1.0 A
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.