Overview

The Combined Valve and Ignition (CVI) system has been developed for application in gas fired domestic central heating boilers, combination boilers and warm air furnaces or water heater appliances with an automatic ignition system.

Features

  • For this system, gas controls have been designed to have the S4565/S4575/S4585 series ignition control attached directly on to the valve.

Product Specifications

Application
Single Stage
Item Type
Product
Frequency
50 Hz
Electrical Connections
Molex 1.1 square pin headers
Voltage
220 Vac; 240 Vac
Operating Temperature Range (F)
5F to 140F
Operating Temperature Range (C)
-15 C to +60 C
Approvals, CE
CE Certified. Report 120808
Body Pattern
Straight-through
Opening Characteristics
Softlite opening
Pressure Ratings (kPa)
45 mbar
Inlet/Outlet Size (in.)
18.6 mm x 18.6 mm
Pilot Gas Outlet
Compression fitting for 4mm. OD tubing
Capacity (m³/hr)
3.4 m³/h (air) at pressure drop of 3 mbar
Pressure Tapping
Euro-style, inlet and outlet
Type of Fuel
Natural; LP; Manufactured
Pressure Regulator Setpoint (kPa)
Softlite: 5 mbar. Full: 9 mbar +/- 1.0 mbar
Ignition Type
Intermittent Pilot