Overview
The Combined Valve and Ignition (CVI) system has been developed for application in gas fired domestic central heating boilers, combination boilers and warm air furnaces or water heater appliances with an automatic ignition system.
Features
- For this system, gas controls have been designed to have the S4565/S4575/S4585 series ignition control attached directly on to the valve.
Product Specifications
- Application
- Single Stage
- Item Type
- Product
- Frequency
- 50 Hz
- Electrical Connections
- Molex 1.1 square pin headers
- Voltage
- 220 Vac; 240 Vac
- Operating Temperature Range (F)
- 5F to 140F
- Operating Temperature Range (C)
- -15 C to +60 C
- Approvals, CE
- CE Certified. Report 120808
- Body Pattern
- Straight-through
- Opening Characteristics
- Softlite opening
- Pressure Ratings (kPa)
- 45 mbar
- Inlet/Outlet Size (in.)
- 18.6 mm x 18.6 mm
- Pilot Gas Outlet
- Compression fitting for 4mm. OD tubing
- Capacity (m³/hr)
- 3.4 m³/h (air) at pressure drop of 3 mbar
- Pressure Tapping
- Euro-style, inlet and outlet
- Type of Fuel
- Natural; LP; Manufactured
- Pressure Regulator Setpoint (kPa)
- Softlite: 5 mbar. Full: 9 mbar +/- 1.0 mbar
- Ignition Type
- Intermittent Pilot