Skip Ribbon Commands
Skip to main content
SharePoint
Login or Register to view pricing and order.
  • Product Info
  • Literature

Overview

The Combined Valve and Ignition (CVI) system has been developed for application in gas fired domestic central heating boilers, combination boilers and warm air furnaces or water heater appliances with an automatic ignition system.

Features

  • For this system, gas controls have been designed to have the S4565/S4575/S4585 series ignition control attached directly on to the valve.

Product Specifications

Application
Single Stage
Dimensions (mm)
148 mm x 105 mm x 6439 mm
Item Type
Product
Frequency
50 Hz
Electrical Connections
Molex 1.1 square pin headers
Voltage
240 Vac
Operating Temperature Range (F)
5F to 140F
Operating Temperature Range (C)
-15 C to +60 C
Body Pattern
Straight-through
Opening Characteristics
Fast Opening with Modureg
Pressure Ratings (kPa)
60 mbar
Inlet/Outlet Size (in.)
1/2 in x 1/2 in BSP
Pilot Gas Outlet
Compression fitting for 4mm. OD tubing
Capacity (m³/hr)
3.4 m³/h (air) at pressure drop of 3 mbar
Pressure Tapping
Euro-style, inlet and outlet
Type of Fuel
Natural; LP; Manufactured
Pressure Regulator Setpoint (kPa)
Max 35 +/- 2 mbar; Min 3 +/- 2 mbar
Ignition Type
Intermittent Pilot
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.