Skip Ribbon Commands
Skip to main content
SharePoint
Login or Register to view pricing and order.
  • Product Info
  • Literature

Overview

The Combined Valve and Ignition system (CVI) has specially been developed for application in gas fired appliances with either intermittent pilot or direct burner ignition.

Features

  • The gas controls have been designed to have the S4565/75/85 series ignition control attached directly onto the valve.
  • The combined system then provides programmed safe light up, flame supervision and regulation of gas flow to the main burner and/or pilot burner of the appliance.
  • The valve (types without pilot outlet) can as well be used as stand alone in direct burner ignition applications.
  • A plug with integrated rectifier circuit then has to be used.
  • The gas controls are approved in accordance with European standards.

Product Specifications

Application
1:1 Gas:Air
Item Type
Product
Mounting
90 degree turned from perpendicular position, side outlet
Frequency
50 Hz; 60 Hz
Electrical Connections
Molex 1.1 square pin headers
Voltage
24 Vac
Operating Temperature Range (F)
32 F to 158 F
Operating Temperature Range (C)
0 C to 70 C
Approvals, CE
CE Certified. Report 120808
Body Pattern
Straight-through
Opening Characteristics
Integrated Gas/Air 1:1
Pressure Ratings (kPa)
60 mbar
Inlet/Outlet Size (in.)
1/2 in. x 1/2 in.
Pilot Gas Outlet
none
Capacity (m³/hr)
3.4 m³/h (air) at pressure drop of 3 mbar
Pressure Tapping
Euro-style, inlet and outlet
Type of Fuel
Natural; LP; Manufactured
Ignition Type
Direct Ignition
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.