Overview
Combination gas controls for use with hot surface/direct spark systems in 24 Vac, gas-fired appliances with capacities from 30 to 415 cfh.
Features
- Controls include manual valve, two automatic operators, and pressure regulator.
- Provide two automatic valves.
- Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.
- Diaphragm operated second automatic valve opens under control of the regulator; closes if gas or power supply is interrupted.
- Meet codes requiring dual safety shutoff.
- Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.
- All adjustments, wiring connections and pilot outlet are accessible from top of control.
- ON-OFF lighting sequence.
Product Specifications
- Application
- Two Stage
- Includes
- Natural to LP Conversion Kit; One 1/2" x 3/8" reducer bushing
- Item Type
- Product
- Frequency
- 60 Hz
- Approvals, Canadian Standards Association
- CSA International: 112395
- Voltage
- 24 Vac
- Operating Temperature Range (F)
- -40 F to +175 F
- Operating Temperature Range (C)
- -40 C to +66 C
- Body Pattern
- Straight-through
- Opening Characteristics
- Standard Opening
- Inlet/Outlet Size (in.)
- 1/2 in. x 1/2 in.
- Type of Fuel
- Natural
- Pressure Regulator Setpoint (in. wc)
- 1.7 in. wc low; 3.5 in. wc high
- Ignition Type
- Direct Ignition
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.