Overview
The VR8301 continuous pilot gas control is for gas-fired appliances with capacities up to 200 ft3/hr at 1 in. wc pressure drop on natural gas. They Include a manual valve, safety shutoff, single automatic operators & pressure regulator.
Features
- Straight-through body pattern.
- Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.
Product Specifications
- Application
- Single Stage
- Dimensions (in.)
- 5 3/8 in. high x 4 1/16 in. wide x 2 11/16 in. deep
- Dimensions (mm)
- 135 mm high x 104 mm wide x 69 mm deep
- Item Type
- Product
- Mounting
- 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
- Frequency
- 50 Hz; 60 Hz
- Approvals, Underwriters Laboratories Inc.
- UL Component Recognized: MH5323
- Approvals, Canadian Standards Association
- CSA International: 112395
- Electrical Connections
- 1/4 in. quick-connect male terminals
- Voltage
- 24 Vac
- Operating Temperature Range (F)
- 0 F to 175 F
- Operating Temperature Range (C)
- -18 C to +79 C
- Body Pattern
- Straight-through
- Opening Characteristics
- Standard Opening
- Pressure Ratings (psi)
- 1/2 psi
- Pressure Ratings (kPa)
- 3.5 kPa
- Inlet/Outlet Size (in.)
- No inlet threads x 3/4 in.
- Pilot Gas Outlet
- Compression fitting for 1/4 in. OD tubing
- Pressure Tapping
- 1/8 in. NPT with plug
- Type of Fuel
- Natural
- Capacity (kBtuh)
- At 1 in. wc p.d.-- 180,000 BTUh: 30,000 BTUh minimum
- Pressure Regulator Setpoint (in. wc)
- 3.5 in. wc
- Pressure Regulator Setpoint (kPa)
- 0.87 kPa
- Ignition Type
- Standing Pilot
- Anticipator Setting
- 0.65 A
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.