Overview
Combination gas control for use with hot surface/direct spark systems in 24 Vac, gas-fired appliances, with capacities from 30 to 415 cfh.
Features
- Controls include manual valve, two automatic operators, and pressure regulator.
- Provide two automatic valves.
- Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.
- Diaphragm operated second automatic valve opens under control of the regulator; closes if gas or power supply is interrupted.
- Meet codes requiring dual safety shutoff.
- Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.
- ON-OFF lighting sequence.
- All adjustments, wiring connections and pilot outlet are accessible from top of control.
- Use VR8305 models with S89C,E,F and S87 series 5 and later.
Product Specifications
- Application
- Single Stage
- Dimensions (in.)
- 5 3/8 in. high x 4 1/16 in. wide x 2 11/16 in. deep
- Dimensions (mm)
- 135 mm high x 104 mm wide x 69 mm deep
- Item Type
- Product
- Mounting
- 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
- Frequency
- 60 Hz
- Approvals, Underwriters Laboratories Inc.
- UL Component Recognized: MH8191
- Approvals, Canadian Standards Association
- CSA International: 112395
- Electrical Connections
- 1/4 in. quick-connect male terminals
- Voltage
- 24 Vac
- Operating Temperature Range (F)
- -40 F to +175 F
- Operating Temperature Range (C)
- -40 C to +79 C
- Body Pattern
- Straight-through
- Opening Characteristics
- Standard Opening
- Pressure Ratings (psi)
- 1/2 psi
- Pressure Ratings (kPa)
- 3.5 kPa
- Inlet/Outlet Size (in.)
- 1/2 in. x 1/2 in.
- Pressure Tapping
- 1/8 in. NPT with plug
- Type of Fuel
- Natural
- Capacity (kBtuh)
- At 1 in. wc p.d.-- 240,000 BTUh: 30,000 BTUh minimum
- Pressure Regulator Setpoint (in. wc)
- 3.5 in. wc
- Pressure Regulator Setpoint (kPa)
- 0.87 kPa
- Ignition Type
- Direct Ignition
- Anticipator Setting
- 0.62 A
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.