Overview
The VR9205Q Direct Ignition Combination 2-Stage Gas Controls are used in gas-fired appliances with up to 140 KBtu/h capacity at 1 in. wc pressure drop. They have been optimized for direct ignition applications and include a manual switch, two automatic operators and a pressure regulator. The valve may be used on either Natural gas or LP gas applications.
Product Specifications
- Application
- Two Stage
- Dimensions (in.)
- 4.04 in high x 5.04 in wide x 3.2 in deep
- Dimensions (mm)
- 103 mm high x 128 mm wide x 81 mm deep
- Includes
- 6 in. wire harness; LP Conversion Kit
- Item Type
- Product
- Mounting
- Any direction
- Frequency
- 50 Hz; 60 Hz
- Approvals, Canadian Standards Association
- CSA International: 112491
- Electrical Connections
- 1/4 in. quick-connect male terminals
- Voltage
- 24 Vac
- Operating Temperature Range (F)
- -40 F to +175 F
- Operating Temperature Range (C)
- -40 C to +79 C
- Body Pattern
- Straight-through
- Opening Characteristics
- Standard Opening
- Pressure Ratings (psi)
- 1/2 psi
- Pressure Ratings (kPa)
- 3.5 kPa
- Inlet/Outlet Size (in.)
- 1/2 in. x 1/2 in.
- Type of Fuel
- Natural (LP if conversion kit included)
- Capacity (kBtuh)
- At 1 in. wc p.d.-- 140,000 BTUh: 20,000 BTUh minimum at high fire, 8,000 BTU minimum at low fire: 200,000 BTUh maximum at max fire
- Pressure Regulator
- Adjustment Range: 0.9 in. wc to 4.0 in. wc
- Pressure Regulator Setpoint (in. wc)
- 1.7 in. wc low; 3.5 in. wc high
- Pressure Regulator Setpoint (kPa)
- 0.42 kPa low; 0.87 kPa high
- Ignition Type
- Direct Ignition
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.