Overview
These gas controls combine a Lite-Rite manual gas cock, safety shutoff Pilotstat assembly, millivoltage automatic valve operator, and optional gas pressure regulator. They require the use of a 750 mV Powerpile generator (thermopile). The generator, heated by the pilot burner flame, provides the electrical energy to operate the combination gas control. A millivoltage thermostat with suitable accessory controls completes the automatic control system for the heating appliance.
Features
- Include pilot flow adjustment screw.
- Easy to install, adjust and service; all adjustments and connections are accessible from top of control.
- Add separate energy cutoff (ECO) where codes call for dual safety shutoff.
- Complete safety shutoff on pilot flame failure.
- LITE-RITE (OFF-PILOT-ON) lighting sequence.
Product Specifications
- Application
- Self-powered automatic control. Use with 750 mV pilot generator.
- Dimensions (in.)
- 4 3/4 in. high x 4 1/16 in. wide x 3 3/16 in. deep
- Dimensions (mm)
- 121 mm high x 103 mm wide x 81 mm deep
- Includes
- Two Bushings: 3/4" NPT to 1/2" NPT and 1/2" NPT to 3/8" NPT; Conversion Kit; Remote Rod Adaptor Knob
- Item Type
- Product
- Mounting
- 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
- Approvals, Underwriters Laboratories Inc.
- UL Component Recognized MCCZ2.MH5323
- Approvals, Canadian Standards Association
- CSA International: 112395
- Tradeline Value
- Universal
- Electrical Connections
- Combination screw and 1/4 in. male quick connects.
- Voltage
- 750 mV
- Operating Temperature Range (F)
- -40F to 175 F
- Operating Temperature Range (C)
- -40 C to +79 C
- Body Pattern
- Straight-through, multi-tapped with 1/2 in. right and left outlets plugged
- Opening Characteristics
- Standard Opening
- Pressure Ratings (psi)
- 1/2 psi
- Pressure Ratings (kPa)
- 3.5 kPa
- Inlet/Outlet Size (in.)
- 3/4 in. NPT x 3/4 in. NPT with 1/2 in. NPT side outlets
- Pilot Gas Outlet
- Compression fitting for 1/4 in. OD tubing.
- Pressure Tapping
- Outlet pressure tap: 1/8 in. NPT with plug
- Type of Fuel
- Natural (LP with included conversion kit)
- Capacity (kBtuh)
- At 1 in. wc p.d.-- 335,000 BTU/hr: 34,000 BTU/hr minimum, 425,000 BTU/hr maximum
- Pressure Regulator
- Standard
- Pressure Regulator Setpoint (in. wc)
- 3.5 in. WC
- Pressure Regulator Setpoint (kPa)
- 0.87 kPa
- Ignition Type
- Standing Pilot