Overview

These gas controls combine a Lite-Rite manual gas cock, safety shutoff Pilotstat assembly, millivoltage automatic valve operator, and optional gas pressure regulator. They require the use of a 750 mV Powerpile generator (thermopile). The generator, heated by the pilot burner flame, provides the electrical energy to operate the combination gas control. A millivoltage thermostat with suitable accessory controls completes the automatic control system for the heating appliance.

Features

  • Include pilot flow adjustment screw.
  • Easy to install, adjust and service; all adjustments and connections are accessible from top of control.
  • Add separate energy cutoff (ECO) where codes call for dual safety shutoff.
  • Complete safety shutoff on pilot flame failure.
  • LITE-RITE (OFF-PILOT-ON) lighting sequence.

Product Specifications

Application
Self-powered automatic control. Use with 750 mV pilot generator.
Dimensions (in.)
4 3/4 in. high x 4 1/16 in. wide x 3 3/16 in. deep
Dimensions (mm)
121 mm high x 103 mm wide x 81 mm deep
Includes
Two Bushings: 3/4" NPT to 1/2" NPT and 1/2" NPT to 3/8" NPT; Conversion Kit; Remote Rod Adaptor Knob
Item Type
Product
Mounting
0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Approvals, Underwriters Laboratories Inc.
UL Component Recognized MCCZ2.MH5323
Approvals, Canadian Standards Association
CSA International: 112395
Tradeline Value
Universal
Electrical Connections
Combination screw and 1/4 in. male quick connects.
Voltage
750 mV
Operating Temperature Range (F)
-40F to 175 F
Operating Temperature Range (C)
-40 C to +79 C
Body Pattern
Straight-through, multi-tapped with 1/2 in. right and left outlets plugged
Opening Characteristics
Standard Opening
Pressure Ratings (psi)
1/2 psi
Pressure Ratings (kPa)
3.5 kPa
Inlet/Outlet Size (in.)
3/4 in. NPT x 3/4 in. NPT with 1/2 in. NPT side outlets
Pilot Gas Outlet
Compression fitting for 1/4 in. OD tubing.
Pressure Tapping
Outlet pressure tap: 1/8 in. NPT with plug
Type of Fuel
Natural (LP with included conversion kit)
Capacity (kBtuh)
At 1 in. wc p.d.-- 335,000 BTU/hr: 34,000 BTU/hr minimum, 425,000 BTU/hr maximum
Pressure Regulator
Standard
Pressure Regulator Setpoint (in. wc)
3.5 in. WC
Pressure Regulator Setpoint (kPa)
0.87 kPa
Ignition Type
Standing Pilot
There is no literature attached to this product, please try another material search. If you believe that there should be literature for this product, please contact Customer Care for website support.