Image 1 of 2
Sales (12)
Submittal (0)
| Title | Date Posted | Size | ||
|---|---|---|---|---|
| No results found for "brochure". |
Training (0)
| Title | Date Posted | Size | ||
|---|---|---|---|---|
| No results found for "brochure". |
Install (3)
| Title | Date Posted | Size | ||
|---|---|---|---|---|
| ST9120B,U Universal Electronic Fan Timers Installation Instructions (English, French) | 06/2020 | 387443 kb |
PDF
|
|
| Installation Instructions for ST9120U Universal Electronic Fan Timers (English) | 10/2020 | 982306 kb |
PDF
|
|
| Technical Reference The Source for Gas Ignition (English) | 11/2022 | 13091028 kb |
PDF
|
| Application | Integrates control of combustion blower and circulating fan operations for a gas warm air appliance |
|---|---|
| Product Features | Replaces 40+ existing Resideo and Honeywell electronic fan timers, Replaceable fuse, DIP switch selectable heat and cool delay on and off times, Electronic air cleaner and humidifier terminal connections, Continuous low speed indoor air circulation |
| Approvals and Standards | UL Listed: Report MP466, CSA Certified: File No. LR95329-41 |
| Postpurge | 5 sec |
| Heat Fan Off Delay Timing | Adjustable 60, 120, 150, or 180 seconds, Set at 120 seconds |
| Heat Fan On Delay Timing | Adjustable 30 or 60 seconds, Set at 30 seconds |
| Cool Fan Off Delay Timing | Adjustable 30 or 60 seconds, Set at 30 seconds |
| Cool Fan On Delay Timing | Adjustable 4 or 30 seconds, Set at 4 seconds |
| Air Cleaner Load Rating | 0.8A maximum combined load at 115 V AC, 0.4A maximum combined load at 230 V AC |
| Thermostat Load Rating | 0.10A plus ignition system load |
| Combution Blower Load Rating | 1.5A full load, 10A locked rotor at 115 Vac, 0.75A full load, 5A locked rotor at 230 Vac (Reduce full load rating by humidifier [HUM] load.) |
| Circulating Fan Load Rating for Heat-Cool Speed | 15A full load, 30A locked rotor at 115 Vac, 7.5A full load, 15A locked rotor at 230 Vac (Reduce full load rating by electronic air cleaner [EAC] load.) |
| Circulating Fan Load Rating for Optional Continuous Speed | 8A full load, 16A locked rotor at 115 Vac, 4A full load, 8A locked rotor at 230 Vac |
| Supply Voltage | Low Voltage: 18 to 30 Vac, Line Voltage: 120V (97-132 Vac), Line Voltage: 240V (196 – 264 Vac) |
| Electrical Ratings | 18 to 30 Vac |
| Power Supply Frequency | 50 Hz, 60 Hz |
| Operating Voltage | 18 to 30 Vac |
| Product Height | 1.5 in |
| Product Length | 5.75 in |
| Product Width | 4.5 in |
| Ambient Operating Temperature (Max) | 175 °F, 79 °C |
| Ambient Operating Temperature (Min) | -40 °F, -40 °C |
| No overview is available for this product. |