Two Rod Intermittent Pilot Control with 90 second trial time, Continuous Retry and Prepurge

S8670K3000/B

2 Rod Intermtt.Pilot Control,90 S./cont.

Find Equivalent or Replacement Products.

  • Product Info
  • Literature

Overview

Provide electronic control of intermittent pilot ignition systems used on gas-fired furnaces, boilers and other heating appliances.

Features

  • Provide ignition sequences, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances.
  • Functional equivalent of S86, S860, and S90 modules. Include spark cable adapter to allow field replacement of S86, S860, and S90 without replacing existing spark cable.
  • Include relay contacts for use with any intermittent pilot gas control string with maximum 1.0A pilot and 2.0A main valve rating; VR8204, VR8304, or VR8440 combination gas control recommended. S8670D is for use with natural or LP gas; modules provide 100 percent pilot gas shutoff and lockout if pilot fails to light.

Product Specifications

Dimensions (in.)
3 15/16 in. high x 5 7/16 in. wide x 2 5/8 in. deep
Dimensions (mm)
100 mm high x 138 mm wide x 67 mm deep
Item Type
Product
Electrical Ratings
24 Vac
Frequency
60 Hz
Approvals, Canadian Standards Association
Design Certified
Flame Failure Response Time (sec)
2 seconds maximum
PrePurge
30 seconds
Ambient Temperature Range (C)
-40 C to +79 C
Ambient Temperature Range (F)
-40 F to +175 F
Ignition System Type
Intermittent Pilot
Ignition Sequence
Continuous Retry
Typical Gas Control
VR8204, VR8304
Type of Gas
Natural or LP
Flame Sense
Two Rod
Ignition Source
Internal high voltage spark generator
Ignition Trials To Lockout
continuous retry
Lockout Timing
continuous retry
Ignition Trial Time (sec)
90 sec
Maximum Valve Load @ 24 Vac (Amps)
1A Pilot, 2A Main @ 24Vac
Typical Ignition Hardware
Q3451
Between Trial Time (sec)
5 minute delay after failed trial for ignition.