Skip Ribbon Commands
Skip to main content
SharePoint
Login or Register to view pricing and order.
Item 4 Of 7
Protectorelay® Oil Burner Control with 45 second safety timing and manual safety switch

R8184G4009/U

Protectorelay® Oil Burner Control with 45 second safety timing, alarm outputs, and manual safety switch

Find Equivalent or Replacement Products.

  • Product Info
  • Literature

Overview

Provides automatic, nonrecycling control of an intermittent ignition oil burner system.

Features

  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat.
  • Solid state flame sensing circuit.
  • LED on terminal strip indicates system lockout (available on some models).
  • Remote lockout indication (available on some models).
  • Enclosed safety switch with external reset button.
  • Manual trip lever opens safety switch for system maintenance.
  • Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing.
  • C554A Cadmium Sulfide Flame Detector and 24 Vac thermostat required..

Product Specifications

Dimensions (in.)
4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep
Dimensions (mm)
111 mm high x 104 mm wide x 64 mm deep
Temperature Range (F)
-40 F to +130 F
Temperature Range (C)
-40 C to +54 C
Comments
With LED for lockout indication, and manual trip lever on safety switch to assure burner shutdown during servicing.
Item Type
Product
Mounting
For mounting on a standard 4 in. X 4 in. junction box or direct mounting on burner housing.
Approvals, Underwriters Laboratories Inc.
UL Component Recognized; File no. MP268, Vol. 35 Sec. 1,3
Approvals, Canadian Standards Association
CSA Certified; File no. LR95329-1
Tradeline Value
Tradeline
Ignition Type
Intermittent
Timing, Safety Switch
45 sec.
Electrical Ratings, Contacts (full load)
7.4 A @ 120 Vac; 3.7 a @ 240 Vac
Electrical Ratings, Contacts (locked rotor)
44.4 A @ 120 Vac; 22.2 A @ 240 Vac
Alarm Load Ratings (pilot duty)
75 VA @ 120/240 Vac, 50-60 Hz; 25 VA @ 24V, 50-60 Hz
Alarm Load Ratings (resistive)
1.5 A @ 120/240V, 50-60Hz; 3 A @ 24 V, 50-60 Hz

Marketing Collateral

Sales/Promotional Materials-Sell Sheet for R8184 Protectorelay Oil Primary Controls (English)

Sales/Promotional Materials-Residential Combustion Gas Controls Quick Reference Guide (English)

Sales/Promotional Materials-Residential Combustion Gas Controls Quick Reference Guide  (English)

Sales/Promotional Materials-Cross Reference Guide for Residential Combustion Heating and Cooling Parts (English)

Sales/Promotional Materials-Brochure for Eastern Canada Inventory Management Guide (Residential Combustion) (English)

Sales/Promotional Materials-Brochure for North-Northwest Inventory Management Guide (Residential Combustion) (English)

Sales/Promotional Materials-2011-2012 Residential Combustion Application Selection and Cross-Reference Guide

Sales/Promotional Materials-Brochure for Residential Combustion Distributor Inventory Management Guide (U.S.) (English)

Sales/Promotional Materials-Brochure for Northeast Inventory Management Guide (Residential Combustion) (English)

Sales/Promotional Materials-Brochure for Central-Western Canada inventory Management Guide (Residential Combustion) (English)

Sales/Promotional Materials-Brochure for Residential Combustion Distributor Inventory Management Guide (Canada) (English)

Sales/Promotional Materials-Brochure for West Inventory Management Guide (Residential Combustion) (English)

Sales/Promotional Materials-Brochure for Mid-Atlantic Inventory Management Guide (Residential Combustion) (English)

Sales/Promotional Materials-Brochure for South-Southeast Inventory Management Guide (Residential Combustion) (English)

Wiring-Wiring for R8184

Wiring-Wire and mount 150�F (66�C) maximum ambient temperature oil primary control

Wiring-Wire and mount 130�F (54�C) maximum ambient temperature oil primary control

Wiring-Internal schematic and hookup for R8184 Oil Burner Control

Wiring-Oil & Hydronic Training

Wiring-Oil & Hydronic Training

Wiring-Oil & Hydronic Training

Wiring-Oil & Hydronic Training

Wiring-Oil & Hydronic Training

Wiring-Protectorelay Control

Wiring-Protectorelay Control

Wiring-Protectorelay Control

Wiring-Electric Fan Timer

Wiring-Electric Fan Timer

Wiring-Protectorelay Control

Wiring-Protectorelay Control

Wiring-Protectorelay Control

Wiring-Electric Fan Timer

Wiring-Typical hookup for R8184N

Wiring-Oil & Hydronic Training

Technical Documents

Product Data and Specifications-Product Data for R4184D, R8184G, R8184N Protectorelay Oil Burner Control (English) - Legacy Product Document

Installation Materials-Regulateurs Primaires Protectorelay-FRENCH - Legacy Product Document

Installation Materials-R4184D; R8184G,M,N,P Protectorelay Oil Primary Controls Installation Instructions (English)

Installation Materials-Installtion Instructions for R8184G Protectorelay Oil Primary (English, French)

Installation Materials-Protectorelay Oil Primary (Addendum to 69-0617-1)

Installation Materials-Installation Instructions for R8184G Protectorelay Oil Primary (English)

Product Data and Specifications-Specification Data for R4184D, R8184G, R8184K, R8184L R4184D, R8184G, K, L Protectorelay Oil Burner Controls (English)

Installation Materials-Replacing R8184G4009 with R7284U Wiring (English)

Installation Materials-Câblages pour remplacer R8184G4009 avec R7284U (French)

Installation Materials-Installation Instructions for R8184G PROTECTORELAY OIL PRIMARY (English)

Installation Materials-Protectorelay Oil Burner Control - English/French

Installation Materials-Protectorelay Oil Primary- English/French

Maintenance/Product Reference Materials-Residential Combustion Application Selection and Cross-Reference Guide (English)

Training

Training Materials-Oil Controls Handbook