Protectorelay® Oil Burner Control, Unit

R8184G4082/U

Protectorelay® Oil Burner Control with 45 second safety timing and alarm outputs

Find Equivalent or Replacement Products.

  • Product Info
  • Literature

Overview

Provides automatic, nonrecycling control of an intermittent ignition oil burner system.

Features

  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat.
  • Solid state flame sensing circuit.
  • LED on terminal strip indicates system lockout (available on some models).
  • Remote lockout indication (available on some models).
  • Enclosed safety switch with external reset button.
  • Manual trip lever opens safety switch for system maintenance.
  • Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing.
  • C554A Cadmium Sulfide Flame Detector and 24 Vac thermostat required..

Product Specifications

Dimensions (in.)
4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep
Dimensions (mm)
111 mm high x 104 mm wide x 64 mm deep
Temperature Range (F)
-40 F to +130 F
Temperature Range (C)
-40 C to +54 C
Includes
Alarm
Comments
With LED for lockout indication, and manual trip lever on safety switch to assure burner shutdown during servicing. Includes remote alarm dry contacts.
Item Type
Product
Mounting
For mounting on a standard 4 in. X 4 in. junction box or direct mounting on burner housing.
Approvals, Underwriters Laboratories Inc.
UL Component Recognized; File no. MP268, Vol. 35 Sec. 1,3
Approvals, Canadian Standards Association
CSA Certified; File no. LR95329-1
Tradeline Value
Tradeline
Ignition Type
Intermittent
Timing, Safety Switch
45 sec.
Electrical Ratings, Contacts (full load)
7.4 A @ 120 Vac; 3.7 a @ 240 Vac
Electrical Ratings, Contacts (locked rotor)
44.4 A @ 120 Vac; 22.2 A @ 240 Vac
Alarm Load Ratings (pilot duty)
75 VA @ 120/240 Vac, 50-60 Hz; 25 VA @ 24V, 50-60 Hz
Alarm Load Ratings (resistive)
1.5 A @ 120/240V, 50-60Hz; 3 A @ 24 V, 50-60 Hz

Marketing Collateral

Sales/Promotional Materials-Brochure for Eastern Canada Inventory Management Guide (Residential Combustion) (English)

Sales/Promotional Materials-Cross Reference Guide for Residential Combustion Heating and Cooling Parts (English)

Sales/Promotional Materials-Brochure for North-Northwest Inventory Management Guide (Residential Combustion) (English)

Sales/Promotional Materials-Residential Combustion Gas Controls Quick Reference Guide  (English)

Sales/Promotional Materials-Sell Sheet for R8184 Protectorelay Oil Primary Controls (English)

Sales/Promotional Materials-2011-2012 Residential Combustion Application Selection and Cross-Reference Guide

Sales/Promotional Materials-Residential Combustion Gas Controls Quick Reference Guide (English)

Sales/Promotional Materials-Brochure for Residential Combustion Distributor Inventory Management Guide (U.S.) (English)

Sales/Promotional Materials-Brochure for Northeast Inventory Management Guide (Residential Combustion) (English)

Sales/Promotional Materials-Brochure for Central-Western Canada inventory Management Guide (Residential Combustion) (English)

Sales/Promotional Materials-Brochure for Residential Combustion Distributor Inventory Management Guide (Canada) (English)

Sales/Promotional Materials-Brochure for West Inventory Management Guide (Residential Combustion) (English)

Sales/Promotional Materials-Brochure for Mid-Atlantic Inventory Management Guide (Residential Combustion) (English)

Sales/Promotional Materials-Brochure for South-Southeast Inventory Management Guide (Residential Combustion) (English)

Wiring-Wiring for R8184

Wiring-Wire and mount 150�F (66�C) maximum ambient temperature oil primary control

Wiring-Wire and mount 130�F (54�C) maximum ambient temperature oil primary control

Wiring-Internal schematic and hookup for R8184 Oil Burner Control

Wiring-Oil & Hydronic Training

Wiring-Oil & Hydronic Training

Wiring-Oil & Hydronic Training

Wiring-Oil & Hydronic Training

Wiring-Oil & Hydronic Training

Wiring-Protectorelay Control

Wiring-Protectorelay Control

Wiring-Protectorelay Control

Wiring-Electric Fan Timer

Wiring-Electric Fan Timer

Wiring-Protectorelay Control

Wiring-Protectorelay Control

Wiring-Protectorelay Control

Wiring-Electric Fan Timer

Wiring-Typical hookup for R8184N

Wiring-Oil & Hydronic Training

Technical Documents

Installation Materials-R4184D; R8184G,M,N,P Protectorelay Oil Primary Controls Installation Instructions (English)

Installation Materials-Installtion Instructions for R8184G Protectorelay Oil Primary (English, French)

Installation Materials-Protectorelay Oil Primary (Addendum to 69-0617-1)

Installation Materials-Protectorelay Oil Burner Control - English/French

Installation Materials-Protectorelay Oil Primary- English/French

Installation Materials-Installation Instructions for R8184G Protectorelay Oil Primary (English)

Product Data and Specifications-Specification Data for R4184D, R8184G, R8184K, R8184L R4184D, R8184G, K, L Protectorelay Oil Burner Controls (English)

Installation Materials-Replacing R8184G4009 with R7284U Wiring (English)

Installation Materials-Câblages pour remplacer R8184G4009 avec R7284U (French)

Installation Materials-Installation Instructions for R8184G PROTECTORELAY OIL PRIMARY (English)

Product Data and Specifications-Product Data for R4184D, R8184G, R8184N Protectorelay Oil Burner Control (English) - Legacy Product Document

Installation Materials-Regulateurs Primaires Protectorelay-FRENCH - Legacy Product Document

Maintenance/Product Reference Materials-Residential Combustion Application Selection and Cross-Reference Guide (English)

Training

Training Materials-Oil Controls Handbook