Universal Hot Surface Ignition Integrated Furnace Control

S9200U1000/U

Universal Hot Surface Ignition Integrated Furnace Control

  • Product Info
  • Literature

Overview

Universal Integrated Furnace Control offers universal compatibility and diagnostics. It replaces a large number of furnace control models in single-stage warm air furnaces. Uses 120Vac hot surface igniter. Includes instructions and special wire harnesses for easy replacement.

Features

  • • Cross reference and wire harnesses provided for simple replacement over 195 existing furnace controls.
  • Main burner ignition using a 120V hot surface igniter.
  • Flame rectification circuit to monitor flame presence.
  • Monitoring of system pressure switch, high temperature limit, and rollout functions.
  • Appliance operation/safety requirements controlled via microprocessor.
  • Controls circulating fan motor based on appliance requirements, in response to a conventional low voltage thermostat.
  • LED system status, performance and diagnostic indication.
  • Twinning capability

Product Specifications

Application
Single stage warm air furnaces
Item Type
Product
Frequency
60 Hz
Operating Humidity Range (% RH)
0% to 95% non-condensing
Operating Temperature Range (F)
-40 F to +175 F
Operating Temperature Range (C)
-40 C to +79 C
Flame Failure Response Time (sec)
2 Seconds max @ 1µA
PrePurge
30 seconds
PostPurge
15 seconds
Cool Fan On Delay
5 seconds
Cool Fan Off Delay
0 or 60 seconds
Line Voltage
120 Vac (97-132 Vac)
Low Voltage
24V (18-30 Vac)
Igniter Current
5 A resistive @ 120VAC
Thermostat Anticipator Setting
(Stage 1 only) 100mA
HSI Warmup Time
17/27 or 30/30 seconds
Trial For Ignition
4, 6, or 8 seconds
Interpurge
60 seconds
Ignition Trials
Three, two retries if flame is not sensed
Number of LEDs
3
Heat On Fan Delay
30 or 60 seconds
Heat Off Fan Delay
60, 90, 120, or 180 Seconds
Gas Control Used With
Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended.
Cooling Contactor Used With
Any 24Vac contactor rated at 1.0A or less
Induced Draft Blower Load
2.2FLA / 25LRA max @120Vac
Ciculator Load
14.5FLA / 25LRA max @120Vac
Type of Fan Used With
Standard Induction-Type Circulating Fan