Material Number Technical Literature Marketing Information Images Competitive Cross-Reference Help
Text in Help dialog, To be determined by the Business
Intermittent Pilot with Comb Air Control. SmartValve®. Two-Stage. Standard Opening. 1/2 x 1/2.
The SmartValve® System Controls combine gas flow control and electronic intermittent pilot sequencing functions into a single unit. The Q3450 or Q3480 Pilot hardware supplies the low voltage igniter, flame sensor and pilot burner. These ignition system controls provide all gas ignition safety functions by controlling gas flow, ignition source, and a 120 Vac or 240 Vac combustion air blower. The controls also monitor the appliance airflow proving switch and limit string to assure proper appliance operation, and provide prepurge, postpurge, and timed trial for pilot ignition with 100 percent shutoff and continuous retry. Includes a diagnostic LED indicates system status.
Wiring-SmartValve
Wiring-SmarValve
Installation Materials-Installation Instructions for SV9540; SV9640 SmartValve™ System Controls (English)
Installation Materials-Installation Instructions for SV9440, SV9540, and SV9640 SmartValve™ System Controls (English)
One 3/4 x 1/2 in. reducer bushings
Two 3/4 x 1/2 in. reducer bushings
Single Stage Natural to LP Gas Conversion Kit. 8" to 12" adjustment range. Includes regulator spring, o-ring, adjustment screw and cap screw
Single Stage LP to Natural Gas Conversion Kit. 3" to 5" adjustment range. Includes regulator spring, o-ring, adjustment screw and cap screw
Two Stage Natural to LP Gas Conversion Kit. 8" to 11" adjustment range.