Two Rod Intermittent Pilot Control with 90 second trial time and Lockout

S8600B3013/B

One Rod Intermittent Pilot Control with 15 second trial time and Lockout

Find Equivalent or Replacement Products.

  • Product Info
  • Literature

Overview

These ignition modules provide ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances.

Features

  • Provide up to 1.0 A pilot and 1.0 main valve current rating.
  • Use a separate igniter and sensor (Q179C with igniter and sensor mounted on one bracket, or Q354 sensor with Q345, Q346, Q348, Q362 or Q381 igniter-sensor recommended.)
  • Can be used on natural on LP gas; they provide 100 percent shutoff on ignition failure.
  • Lock out on shutoff.
  • Manual reset is required.

Product Specifications

Dimensions (in.)
3 15/16 in. high x 5 7/16 in. wide x 2 5/8 in. deep
Dimensions (mm)
100 mm high x 138 mm wide x 67 mm deep
Item Type
Product
Electrical Ratings
24 Vac
Frequency
60 Hz
Approvals, Canadian Standards Association
Design Certified
Flame Failure Response Time (sec)
2 seconds maximum
PrePurge
None
Ambient Temperature Range (C)
-40 C to +79 C
Ambient Temperature Range (F)
-40 F to +175 F
Ignition System Type
Intermittent Pilot
Ignition Sequence
Lockout
Typical Gas Control
VR8204, VR8304
Type of Gas
Natural or LP
Flame Sense
Two Rod
Ignition Source
Internal high voltage spark generator
Ignition Trials To Lockout
1
Lockout Timing
90 seconds
Ignition Trial Time (sec)
90 sec
Maximum Valve Load @ 24 Vac (Amps)
1A Pilot, 1A Main @ 24Vac
Typical Ignition Hardware
Q3452