Skip Ribbon Commands
Skip to main content
SharePoint
Login or Register to view pricing and order.
Item 1 Of 1
2 Rod Automatic Ignition Control with 10 second trial time

S4567A 1019B

2 Rod Automatic Ignition Control with 10 second trial time

  • Product Info
  • Literature

Product Specifications

Used With
VK4105A1126
Item Type
Product
Electrical Ratings
110 / 120 Vac
Frequency
50 Hz; 60 Hz
PrePurge
None
Ambient Temperature Range (C)
-15 C to +60 C
Ambient Temperature Range (F)
5 F to 140 F
Ignition System Type
Direct Spark Ignition
Ignition Sequence
Non-Volatile Lockout
Type of Gas
Natural or LP
Flame Sense
Two Rod
Ignition Source
Internal high voltage spark generator
Ignition Trials To Lockout
continuous retry
Lockout Timing
10 sec.
Ignition Trial Time (sec)
10 sec.
Maximum Valve Load @ 24 Vac (Amps)
1A Main @ 220Vac
Approvals, American Gas Association
EN298 - 1993