Skip Ribbon Commands
Skip to main content
SharePoint
Login or Register to view pricing and order.
Item 3 Of 3
Direct Ignition Combination 2-Stage Gas Control

VR9205Q1507/U

24 Vac Direct Ignition Combination 2-Stage Gas Controls

  • Product Info
  • Literature

Overview

The VR9205Q Direct Ignition Combination 2-Stage Gas Controls are used in gas-fired appliances with up to 140 KBtu/h capacity at 1 in. wc pressure drop. They have been optimized for direct ignition applications and include a manual switch, two automatic operators and a pressure regulator. The valve may be used on either Natural gas or LP gas applications.

Product Specifications

Application
Two Stage
Dimensions (in.)
4.04 in high x 5.04 in wide x 3.2 in deep
Dimensions (mm)
103 mm high x 128 mm wide x 81 mm deep
Includes
6 in. wire harness; LP Conversion Kit
Item Type
Product
Mounting
Any direction
Frequency
50 Hz; 60 Hz
Approvals, Canadian Standards Association
CSA International: 112491
Electrical Connections
1/4 in. quick-connect male terminals
Voltage
24 Vac
Operating Temperature Range (F)
-40 F to +175 F
Operating Temperature Range (C)
-40 C to +79 C
Body Pattern
Straight-through
Opening Characteristics
Standard Opening
Pressure Ratings (psi)
1/2 psi
Pressure Ratings (kPa)
3.5 kPa
Inlet/Outlet Size (in.)
1/2 in. x 1/2 in.
Type of Fuel
Natural (LP if conversion kit included)
Capacity (kBtuh)
At 1 in. wc p.d.-- 140,000 BTUh: 20,000 BTUh minimum at high fire, 8,000 BTU minimum at low fire: 200,000 BTUh maximum at max fire
Pressure Regulator
Adjustment Range: 0.9 in. wc to 4.0 in. wc
Pressure Regulator Setpoint (in. wc)
1.7 in. wc low; 3.5 in. wc high
Pressure Regulator Setpoint (kPa)
0.42 kPa low; 0.87 kPa high
Ignition Type
Direct Ignition