One or Two Rod Intermittent Pilot Control with continuous retry trial time with configurable lockout timing of 15 or 90 seconds and configurable prepurge of 30 seconds or no prepurge

S8610U3009/U

Universal Intermittent Pilot Ignition Module

This product is available in Canada only.

  • Product Info
  • Literature
  • Accessories & Replacement Parts

Overview

Universal intermittent pilot ignition module replaces multiple field installed intermittent pilot modules supplied by Resideo, Robertshaw, Johnson, and UTEC (HSC). Uses existing intermittent pilot burner. Includes cross reference, instructions, and accessories for easy replacement.

Features

  • Replaces over 400 White-Rogers, Robertshaw and Resideo intermittent pilot ignition modules
  • Provides ignition sequencing, flame monitoring and safety shutoff for intermittent pilot warm air furnaces and heating appliances
  • Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed.
  • For use with Natural or LP gas
  • For use in single rod or dual rod/remote sense applications
  • Includes spark cable adapters to allow field replacement of both Resideo and competitive controls without replacing existing spark cable.

Product Specifications

Dimensions (in.)
3 15/16 in. high x 5 7/16 in. wide x 2 5/8 in. deep
Dimensions (mm)
100 mm high x 138 mm wide x 67 mm deep
Includes
Damper connection with automatic vent damper plug
Item Type
Product
Electrical Ratings
24 Vac
Frequency
60 Hz
Approvals, Canadian Standards Association
Design Certified
Tradeline Value
Tradeline
Flame Failure Response Time (sec)
2 seconds maximum
PrePurge
Configurable to 30 seconds or no prepurge
Ambient Temperature Range (C)
-40 C to +74 C
Ambient Temperature Range (F)
-40 F to +165 F
Ignition System Type
Intermittent Pilot
Ignition Sequence
Continuous Retry
Typical Gas Control
VR8204, VR8304
Type of Gas
Natural or LP
Flame Sense
Single Rod or Two Rods
Ignition Source
Internal high voltage spark generator
Ignition Trials To Lockout
continuous retry
Lockout Timing
continuous retry
Ignition Trial Time (sec)
15 or 90 sec
Maximum Valve Load @ 24 Vac (Amps)
1A Pilot, 2A Main @ 165 F; 1A Pilot, 1A Main @ 175 F
Typical Ignition Hardware
Q345, Q3451, Q3452
Between Trial Time (sec)
5 minute delay after failed trial for ignition.

Marketing Collateral

Sales/Promotional Materials-Residential Combustion Gas Controls Quick Reference Guide (laminated)

Sales/Promotional Materials-Sell Sheet for S8610U Universal Hot Surface Ignition Module (French)

Sales/Promotional Materials-The Universal Choice Selector Guide/Cross Reference - Residential Combustion (English)

Sales/Promotional Materials-Sell Sheet for S8610U3009 Universal Intermittent Pilot Control (English)

Sales/Promotional Materials-Residential Combustion Product Restocking Notepad (English)

Sales/Promotional Materials-Brochure for Universal Replacement Parts (Residential Combustion) (English)

Sales/Promotional Materials-Sell Sheet for Y8427U, S8610U, ST9120U, S9200U, Q3200U Universal Service Kit Promotion (Distributors) (English)

Sales/Promotional Materials-Counter mat for Universal Replacement Products (Residential Combustion) (English)

Sales/Promotional Materials-Sell Sheet for Q3200U, R7284U, ST9120U, S8610U, S9200U Universal Parts Learn and Earn Training (English)

Sales/Promotional Materials-Sell Sheet for Y8427U, S8610U, ST9120U, S9200U, Q3200U Universal Service Kit Promotion (Contractors) (English)

Sales/Promotional Materials-Brochure for Honeywell versus White-Rodgers Universal Replacement Intermittent Pilot Controls (English)

Sales/Promotional Materials-Universal Service Parts header card

Sales/Promotional Materials-Sell Sheet for S8610U3009 Universal Intermittent Pilot Control (Spanish)

Dimension-Approximate dimentions for inginton module

Wiring-S8910U

Technical Documents

Maintenance/Product Reference Materials-Technician's Quick Reference Guide for S8610U Universal Intermittent Pilot Gas Ignition Control (English

Maintenance/Product Reference Materials-Residential Combustion Application Selection and Cross-Reference Guide (English)

Installation Materials-Universal Intermittent Pilot Module-SUPER TRADELINE - Legacy Product Document

Installation Materials-Installation Instructions for S8610U Universal Intermittent Pilot Gas Ignition Control (English)

Installation Materials-Notice d'installation - Régulateur d'allumage à gaz à veilleuse intermittente universel S8610U (French)

Product Data and Specifications-Product Data for S8610U Universal Intermittent Pilot Module (English)

Product Data and Specifications-Product Data for S8610U Modulo Universal de Piloto Intermitente (Spanish)

Maintenance/Product Reference Materials-A Universal Replacement for IP Ignition Modules - The Honeywell S8610U Electronic Control Module

Accessories

394800-30/U

30" Ignition Cable Assembly with right angle boot for pilot burner connection

394801-30/U

30 in. ignition cable assembly with a straight boot for pilot burner connection