1/2 in. NPT x 1/2 in. NPT Direct Hot Surface Ignition SmartValve® Control with standard opening and 3.5 in. wc pressure regulator setting

SV9520M2536/U

Direct Hot Surface Ignition SmartValve® Control. Standard Opening. Set 3.5" WC. 7 sec HSI Warm-Up.

  • Product Info
  • Literature
  • Accessories & Replacement Parts

Overview

The SmartValve® System Controls combine gas flow control and electronic direct main burner ignition sequencing functions into a single unit. The ignition source is 120V hot surface igniter lighting the main burner flame. Provides all gas ignition safety functions by controlling gas flow, ignition source, and a 120 Vac combustion air blower. The control also monitors the appliance airflow proving switch circuit and limit string to assure proper appliance operation. The SmartValve System Controls provide prepurge, postpurge and timed trial for ignition with multiple ignition trials and auto reset from lockout. Diagnostic LED indicates system status.

Features

  • The control communicates directly with the ST9160 Electronic Fan Timer (EFT) in typical forced warm air furnace applications.
  • It can directly interface with the appropriate power supplies and a system thermostat for additional appliance applications.
  • When controlled directly by a thermostat, the control does not provide a postpurge function, as power to the control is removed when the thermostat call for heat ends.
  • This system is suitable for a wide range of fan-assisted combustion, gas-fired appliances including furnaces, rooftop furnaces, boilers, unit heaters, infrared heaters, water heaters and commercial cooking appliances.

Product Specifications

Dimensions (in.)
3.2 in. wide x 4.9 in. high x 4.1 in.long
Dimensions (mm)
81 mm wide x124 mm high x 104 mm long.
Includes
LP Conversion Kit
Item Type
Product
Mounting
0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Electrical Ratings
24 Vac
Frequency
50 Hz; 60 Hz
Approvals, Canadian Standards Association
CSA International: 112395
Tradeline Value
Universal
Flame Failure Response Time (sec)
2 sec @ 5 µA
PrePurge
15 seconds
Ambient Temperature Range (C)
-40 C to +79 C
Ambient Temperature Range (F)
-40 F to +175 F
Ignition System Type
Direct Hot Surface Ignition
Ignition Sequence
7/12 sec
Type of Gas
Natural (LP with included conversion kit)
Flame Sense
HSI
Ignition Source
HSI
Ignition Trials To Lockout
4 trials
Ignition Trial Time (sec)
7 sec
Typical Ignition Hardware
Norton 601
Body Pattern
Straight-through
Opening Characteristics
Standard
Pressure Regulator Setting (psi)
3.5 in. WC
Pressure Regulator Setting (kPa)
0.87 kPa
Pressure Ratings (psi)
1/2 psi
Pressure Ratings (kPa)
3.5 kPa
Inlet/Outlet Size (in.)
1/2 in. NPT x 1/2 in. NPT
Pilot Gas Outlet
No
Capacity (ft³/hr)
Maximum at 1 in. P.D.--150 ft³/hr; Maximum--200 ft³/hr; Minimum--20 ft³/hr
Capacity (m³/hr)
Maximum at 1 in. P.D.--4.2 m³/hr; Maximum--5.7 m³/hr; Minimum--0.6 m³/hr
Pressure Tapping
1/8 in. - NPT

Accessories

393691/U

Single Stage Natural to LP Gas Conversion Kit. 8" to 12" adjustment range. Includes regulator spring, o-ring, adjustment screw and cap screw

394588/U